Content Menu

Understanding HPLC 2205 Capillary Tubing

>> What is Duplex 2205 Capillary Tubing?

>> Importance in HPLC Systems

Best Practices to Extend the Lifespan of HPLC 2205 Capillary Tubing

>> 1. Proper Installation and Handling

>> 2. Regular Cleaning and Inspection

>> 3. Preventing Corrosion

>> 4. Optimal Tubing Dimensions and Length

>> 5. Prevent Mechanical Stress and Fatigue

Maintenance Procedures for HPLC 2205 Capillary Tubing

>> Routine Maintenance Checklist

>> Replacing and Installing Tubing

Conclusion

Frequently Asked Questions (FAQs)

>> 1. What makes Duplex 2205 capillary tubing better than standard stainless steel tubing?

>> 2. How often should I inspect and clean my HPLC 2205 capillary tubing?

>> 3. Can I bend HPLC 2205 capillary tubing to fit my system layout?

>> 4. What are the signs that my HPLC 2205 capillary tubing needs replacement?

>> 5. How do I properly connect fittings to HPLC 2205 capillary tubing?

Citations:

High-Performance Liquid Chromatography (HPLC) is a critical analytical technique used in many scientific fields, from pharmaceuticals to environmental testing. Central to the performance and reliability of an HPLC system is the quality and durability of its components, particularly the capillary tubing. The HPLC 2205 capillary tubing, made from Duplex Stainless Steel 2205, is renowned for its superior strength, corrosion resistance, and durability, making it a preferred choice for demanding HPLC applications. Extending the lifespan of this tubing not only ensures consistent analytical results but also reduces downtime and maintenance costs.

This comprehensive guide will explore best practices, maintenance tips, and handling procedures to maximize the longevity of your HPLC 2205 capillary tubing. We will also include visual aids and videos to help you implement these strategies effectively.

825 Seamless Coil tubing Comtrol Line

Understanding HPLC 2205 Capillary Tubing

What is Duplex 2205 Capillary Tubing?

Duplex 2205 is a nitrogen-enhanced stainless steel alloy that combines austenitic and ferritic phases, offering high tensile strength and excellent corrosion resistance. This makes Duplex 2205 capillary tubing ideal for high-pressure and corrosive environments typical in HPLC systems.

- Superior mechanical properties: Duplex 2205 has nearly double the yield strength of traditional stainless steel 316L, allowing it to withstand higher pressures without deformation.

- Corrosion resistance: Its high chromium, molybdenum, and nitrogen content provide excellent resistance to pitting and crevice corrosion, common issues in chemical injection and analytical applications.

- Precision manufacturing: The tubing is manufactured with tight tolerances on internal diameter (ID) and outer diameter (OD), ensuring minimal dead volume and optimal flow characteristics in HPLC systems.

Importance in HPLC Systems

The HPLC 2205 capillary tubing connects various modules within the HPLC instrument, such as pumps, columns, and detectors. Its quality directly influences:

- Flow stability and pressure resistance

- Minimization of sample dispersion and band broadening

- Prevention of contamination and leaks

Best Practices to Extend the Lifespan of HPLC 2205 Capillary Tubing

1. Proper Installation and Handling

- Use correct fittings and swaging techniques: Properly swaging stainless steel fittings onto the tubing ensures leak-free connections and prevents tubing damage. Avoid over-tightening, which can deform the ferrule or tubing.

- Avoid bending beyond recommended radii: Sharp bends or kinks can weaken the tubing structure and cause premature failure.

- Keep tubing ends clean and burr-free: Flat, smooth ends prevent dead volume pockets and ensure uniform sealing.

2. Regular Cleaning and Inspection

- Routine cleaning: Flush the tubing with appropriate solvents to remove residues and prevent clogging. Use mild cleaning agents to avoid surface damage.

- Visual inspections: Regularly check for signs of corrosion, discoloration, or physical damage. Early detection of wear or corrosion spots can prevent leaks and maintain system integrity.

- Avoid abrasive cleaners: Use soft cloths and mild soap solutions for cleaning external surfaces.

3. Preventing Corrosion

Although Duplex 2205 is highly corrosion-resistant, certain practices help maintain its protective qualities:

- Avoid contact with corrosive chemicals: Minimize exposure to acids, salts, and harsh chemicals. If exposure occurs, promptly rinse and dry the tubing.

- Maintain proper storage conditions: Store tubing in dry, clean environments to prevent surface oxidation.

- Use seal wash options in pumps: Seal wash systems reduce salt build-up and extend tubing and pump seal life.

4. Optimal Tubing Dimensions and Length

- Select appropriate inner diameter: Smaller IDs reduce band broadening but increase pressure. Balance ID with system pressure limits and flow requirements.

- Minimize tubing length: Longer tubing increases dead volume and sample dispersion. Use the shortest length that maintains system functionality.

5. Prevent Mechanical Stress and Fatigue

- Avoid excessive vibration and movement: Secure tubing to prevent mechanical fatigue and wear.

- Use coiled tubing when appropriate: Coiled tubing can absorb mechanical stress and reduce damage from bending.

2205 duplex stainless steel capillary tubing_3

Maintenance Procedures for HPLC 2205 Capillary Tubing

Routine Maintenance Checklist

- Flush tubing with compatible solvents after each use.

- Inspect fittings and ferrules for wear or deformation.

- Replace damaged or corroded tubing segments immediately.

- Use pressure testing to detect leaks.

- Maintain pump seals and valves to reduce stress on tubing.

Replacing and Installing Tubing

- Remove tubing carefully to avoid damaging fittings.

- Use pliers to twist off ferrules when replacing tubing.

- Clean fittings of debris before installing new tubing.

- Insert tubing fully into fittings and engage locking mechanisms properly.

Conclusion

The HPLC 2205 capillary tubing is a vital component in ensuring the reliability and accuracy of high-performance liquid chromatography systems. Its superior mechanical strength and corrosion resistance make it an excellent choice for demanding analytical environments. However, to maximize its lifespan, proper installation, regular cleaning, careful handling, and routine inspection are essential. By following the best practices and maintenance procedures outlined in this guide, users can significantly extend the operational life of their HPLC 2205 capillary tubing, reduce downtime, and maintain optimal chromatographic performance.

2507 Duplex Coiled Tubing_2

Frequently Asked Questions (FAQs)

1. What makes Duplex 2205 capillary tubing better than standard stainless steel tubing?

Duplex 2205 offers higher tensile strength, better corrosion resistance, and longer service life compared to standard stainless steel 316L. It withstands higher pressures and harsh chemical environments, making it ideal for demanding HPLC applications.

2. How often should I inspect and clean my HPLC 2205 capillary tubing?

Inspection and cleaning should be performed regularly, ideally after every batch of analysis or at least monthly. Frequent maintenance prevents clogging, corrosion, and ensures consistent chromatographic performance.

3. Can I bend HPLC 2205 capillary tubing to fit my system layout?

Yes, but only within the recommended bend radius specified by the manufacturer. Excessive bending or kinking can weaken the tubing and cause leaks or flow restrictions.

4. What are the signs that my HPLC 2205 capillary tubing needs replacement?

Signs include visible corrosion, leaks, pressure drops, increased baseline noise, or inconsistent retention times. Any physical damage or deformation also warrants immediate replacement.

5. How do I properly connect fittings to HPLC 2205 capillary tubing?

Use the correct swaging tools and techniques to attach fittings. Avoid over-tightening to prevent ferrule deformation. Ensure tubing ends are clean and burr-free before installation for a secure, leak-free connection.

Citations:

[1] https://www.agilent.com/cs/library/usermanuals/public/G7110-G7111-G5654-Iso-Quat-Pumps_UseMa-en-SD-29000225.pdf

[2] https://www.simplexfittings.com/blog/how-to-prevent-corrosion-in-duplex-2205-round-bars-maintenance-tips-and-tricks/

[3] https://www.geopsi.com/blog/the-best-material-for-downhole-capillary-tube-duplex-2205-vs-stainless-steel-316l/

[4] https://widesteel.com/product/duplex-2205-capillary-tube-manufacture-in-china/

[5] https://www.youtube.com/watch?v=iTilOMH51Uc

[6] https://community.agilent.com/knowledge/lc-portal/m/lc-videos/705

[7] https://www.kromasil.com/support/faq.php?FAQelkiu

[8] https://uhplcs.com/hplc-capillary-tubing/

[9] https://www.sscoiledtubing.com/products/ss_coiled_tubing/duplex_2205_coiled_tubing/duplex_2205_stainless_steel_coiled_tubing_1_4___718523.html

[10] https://www.agilent.com/cs/library/usermanuals/public/G7111AUser.pdf

[11] https://www.agilent.com/cs/library/slidepresentation/public/care-and-feeding-of-your-hplc-system-july162024.pdf

[12] https://www.handytube.com/technical-resources/blog/why-high-pressure-tubing-is-essential-for-hplc

[13] https://www.samaterials.com/ct5417-duplex-stainless-steel-2205-capillary-tube.html

[14] https://www.thermofisher.com/us/en/home/industrial/chromatography/chromatography-learning-center/high-performance-liquid-chromatography-hplc-support/hplc-instrument-maintenance/hplc-maintenance-videos.html

[15] https://widesteel.com/product/duplex-2205-coiled-capillary-tubing-3-8-inch-od0-035-inch-wt-manufacture-in-chin/

[16] https://www.elementlabsolutions.com/uk/agilent-stainless-steel-capillaries-for-hplc

[17] https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/600/187/hplc-columns-guide-br7614en-ms.pdf

[18] https://dspace.library.uu.nl/bitstream/handle/1874/23762/full.pdf?sequence=11&isAllowed=y

[19] https://www.mdpi.com/1420-3049/21/11/1576

[20] https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/128/929/4497.pdf

[21] https://tobias-lib.ub.uni-tuebingen.de/xmlui/bitstream/handle/10900/151054/Dissertation_Simon_Jaag.pdf?sequence=1&isAllowed=y

[22] https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/600/187/hplc-columns-guide-br7614en-ms.pdf

[23] https://www.sscontrolline.com/stainless-steel-capillary-tubing-manufacturer.html

[24] https://www.labcompare.com/10-Featured-Articles/617988-Troubleshooting-Common-HPLC-Issues/

[25] https://apps.dtic.mil/sti/tr/pdf/ADA191176.pdf

[26] https://www.youtube.com/watch?v=iTilOMH51Uc

[27] https://www.phenomenex.com/-/jssmedia/phxjss/data/media/documents/1566905739-ct1224-acc.pdf?rev=13cb3862d2ab41e682668a0271356807

[28] https://www.sigmaaldrich.com/US/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/hplc-troubleshooting-guide

[29] https://widesteel.com/product/duplex-2205-capillary-tubing/

[30] https://www.agilent.com/store/zh_CN/Prod-160-2205-5/160-2205-5

[31] https://www.youtube.com/watch?v=cXEEYyNeCEk

[32] https://www.agilent.com/en/product/liquid-chromatography/hplc-supplies-accessories/capillary-fittings-connectors-for-hplc/capillaries-for-hplc

[33] https://www.geopsi.com/products/capillary-tube/0-250-capillary-tube-duplex-2205-035/

[34] https://www.youtube.com/watch?v=8m3LdmgiPnU

[35] https://www.youtube.com/watch?v=5tGoQ8JZoPc

[36] https://mm.made-in-china.com/product/High-Glossy-ASTM-AISI-202-316-403-409-316-Stainless-Steel-Capillary-Tubing-for-HPLC-Industrial-Chromatography-2181750265.html

[37] https://www.tjtgsteel.com/aisi-316-316l-stainless-steel-capillary-tubing.html

[38] https://widesteel.com/product/duplex-2205-control-line-3-8-inch0-049-inch/

[39] https://www.youtube.com/watch?v=AcnAtLVNMBY

[40] https://www.restek.com/global/it/articles/frequently-asked-questions-hplc-and-uhplc

[41] https://widesteel.com/product/ss304-capillary-tubing-3-8-inch-0-049-inch/

[42] https://www.restek.com/chromablography/why-tubing-and-fittings-matter-in-hplc-uhplc-don%E2%80%99t-overlook-the-little-things

[43] https://www.geopsi.com/wp-content/uploads/2023/06/Why-Duplex-2205-Is-Better-Than-SS316L-for-Capillary-Tube.pdf

[44] https://tubingcentral.com/products/alloys/2205-duplex/

[45] http://www.chromforum.org/viewtopic.php?t=84984

[46] https://www.agilent.com/cs/library/usermanuals/public/G1312-90015_BinPump-B_USR_EN.pdf

[47] https://asset.library.wisc.edu/1711.dl/EZFQMBKZITNSS85/R/file-267d2.pdf

[48] https://www.chromtech.net.au/pdf2/Tubing-2018Update.pdf

[49] http://www.chromforum.org/viewtopic.php?t=10774

[50] https://patents.google.com/patent/US8822148B2/en

[51] https://mdpi-res.com/bookfiles/book/5481/Derivatization_in_Analytical_Chemistry.pdf?v=1742609171

[52] https://scioninstruments.com/blog/hplc-troubleshooting-guide-2/

[53] https://www.analytics-shop.com/gb/re25740

[54] https://widesteel.com/product/incoloy-825-capillary-tubing-3-8-inch-od-0-049inch/

[55] https://www.handytube.com/technical-resources/blog/why-high-pressure-tubing-is-essential-for-hplc

[56] https://www.thermofisher.com/hk/zt/home/industrial/chromatography/chromatography-learning-center/high-performance-liquid-chromatography-hplc-support/hplc-troubleshooting.html

Content Menu

Related Products

Leave Us Your Info
  • logo
  • Sign up for our newsletter
  • get ready for the future
    sign up for our newsletter to get updates straight to your inbox